Hard-shell chambers · researched 11 November 2026
Perry Baromedical review: FDA status, pressure and what buyers report
Every fact below links to the page or record it came from. Perry Baromedical chambers were checked against FDA's own databases, pressure claims against the 510(k) on file, and buyer reports on Reddit, Trustpilot, BBB and Amazon. A second researcher re-checked the record, 42 items, and corrected or removed what did not hold.
- Company
- Perry Baromedical Corporation
- FDA status
- Holds an FDA 510(k) for its device
- Prices found
- Not published
- Website
- perrybaromedical.com
Documentation score
4 of 5
Well documented
- FDA 510(k) names its chamber
- Advertised pressure within the clearance
- Pressure-vessel standard shown
- FDA registration on record
- No material claim contradicted
Customer record
1 of 3
Weak customer record
- Rated 4.0 or better on 50 or more reviews
- BBB rating A- or better
- No complaint repeated across 3 or more sources
Perry Baromedical chambers on record
| Model | Type | Pressure claimed | Oxygen | Price | Warranty |
|---|---|---|---|---|---|
| SIGMA 40 | hard chamber | Maximum Operating Pressure 30 psi / 3 ATA (2.07 bar) | Standard system 'pressurized with USP Medical Grade Oxygen'; air pressurization possible with wall-mounted air/oxygen select valve manifold (Sigma Series product advisory) | Not published | Not stated |
| SIGMA 36 | hard chamber | Maximum Operating Pressure 30 psi / 3 ATA (2.07 bar) | Standard system 'pressurized with USP Medical Grade Oxygen'; air pressurization possible with wall-mounted air/oxygen select valve manifold (Sigma Series product advisory) | Not published | Not stated |
| SIGMA 34 | hard chamber | 30 psi/3 ATA (2.07 bar) | Standard system 'pressurized with USP Medical Grade Oxygen'; air pressurization possible with wall-mounted air/oxygen select valve manifold (Sigma Series product advisory); 'Air/Oxygen Select Capability Option' | Not published | 'One Year Warranty' (Sigma 34 page) |
| SIGMA ICON 30 | hard chamber | '3.0 ATA Full Depth'; Maximum Operating Pressure 30 psig (66 FSW) 2.07 bar (3 ATA) | Oxygen supply plus BIBS supply (air or O2) per spec table | Not published | Not stated |
| SIGMA Elite (34 / 36 / 40) | hard chamber | Not exceeding 3 ATA (K072427) | 'pressurized and ventilated continuously with pure oxygen' (K072427 summary) | Not published | Not stated |
| SIGMA 40-II (dualplace) | hard chamber (two patients) | Maximum Operating Pressure 30 psig (66 FSW) 2.07 bar (3 ATA) | 'pressurized with breathing quality air'; patients breathe pure oxygen through BIBS 'Duke' style hoods | Not published | Not stated |
| SIGMA MP (multiplace) | hard chamber (multiplace) | Not stated on current page (MAUDE report names a 'SIGMA MP 84" 6ATA' unit) | Not stated | Not published | Not stated |
| BARA-MED acrylic monoplace | hard chamber | 'pressures not exceeding 3 ATA' (K020974 summary, held by ETC) | Not stated | Not published | Not stated |
| Used / refurbished chambers | hard chamber | Varies | Not stated | Not published | 'OEM bumper to bumper warranty' (terms not stated) |
Is Perry Baromedical FDA cleared?
| 510(k) | Held by | Cleared device | Decision | Cleared for | Pressure |
|---|---|---|---|---|---|
| K072427 | Perry Baromedical Corp. | SIGMA SERIES HYPERBARIC CHAMBER | 2008-06-11 | 'The SIGMA Elite 34, 36 and 40 Monoplace Hyperbaric Chambers are intended for use for the following clinical medical conditions in accordance with guidelines established by the Undersea and Hyperbaric Medical Society, as follows: 1. Air or Gas Embolism 2. Carbon Monoxide / Smoke Inhalation 3. Compromised Skin Grafts and Flaps 4. Crush Injuries / Acute Traumatic Ischemia 5. Decompression Sickness 6. Enhanced Healing in Selected Problem Wounds 7. Exceptional Blood Loss (Anemia) 8. Gas Gangrene (Clostridia Myonecrosis) 9. Intracranial Abscess 10. Necrotizing Soft Tissue Infections 11. Radiation Tissue Damage (Osteoradionecrosis) 12. Refractory Osteomyelitis 13. Thermal Burns' Prescription Use. (OCR text; scan errors such as 'Bums' corrected to 'Burns') | 'a prescription device intended for the whole body administration of oxygen to a patient at pressures not exceeding 3 ATA'; 'pressurized and ventilated continuously with pure oxygen' |
| K990927 | Perry Baromedical Corp. | SIGMA 3400 MONOPLACE HYPERBARIC CHAMBER | 1999-11-12 | 'The SIGMA 3400 Monoplace Hyperbaric Chamber is indicated for use for the following clinical medical conditions in accordance with guidelines established by the Undersea and Hyperbaric Medical Society' followed by the same UHMS list (OCR of scanned PDF) | Summary (OCR): 'The medium used for pressurization of the chamber is medical grade oxygen'; numeric pressure not legible in scan |
| K974868 | Perry Baromedical Corp. | SIGMA PLUS MONOPLACE HYPERBARIC CHAMBER | 1998-07-02 | 'The monoplace hyperbaric chamber is indicated for use for the following clinical medical conditions in accordance with guidelines established by the Undersea and Hyperbaric Medical Society' followed by the UHMS list (OCR of scanned PDF) | Not legible in scan; pressurization 'either compressed pure oxygen or' breathing air with hood or mask |
| K983648 | Perry Baromedical Services | SIGMA PLUS/ II MULTIPLACE HYPERBARIC SYSTEM | 1999-02-24 | 'The SIGMA Plus / II Multiplace hyperbaric System is indicated for use for the following clinical medical conditions in accordance with guidelines established by the Undersea and Hyperbaric Medical Society' (list not legible in OCR) | Not stated |
| K930748 | Perry Baromedical Services | SIGMA MP MULTIPLACE HYPERBARIC CHAMBER | 1993-08-20 | Summary not readable | Not stated |
| K862198 | Perry Baromedical Services (Great Neck, NY) | SIGMA II - DUAL PLACE HYPERBARIC CHAMBER | 1986-11-12 | Summary not readable | Not stated |
| K895513 | Perry Baromedical Services | PERRY SV-1 HYPERBARIC VENTILATOR | 1990-12-19 | Summary not readable | Not stated |
| K832127 | Nautilus Environmedical Systems, Inc. (Walker, MI) | NAUTILUS MONOPLACE HYPERBARIC UNIT | 1983-08-12 | Summary not readable | Not stated |
| K020974 | Environmental Tectonics Corp. | BARA-MED ACRYLIC MONOPLACE HYPERBARIC CHAMBER | 2002-06-26 | Summary: prescription device for administration of oxygen 'at pressures not exceeding 3 ATA' (see PDF) | 3 ATA |
| K993010 | Environmental Tectonics Corp. | BARA-MED, ACRYLIC MONOPLACE HYPERBARIC CHAMBER | 2000-05-30 | Summary not readable | Not stated |
| K092991 | Environmental Tectonics Corp. | O.S.C.A.R. (OPERATING SYSTEM FOR CONTROL AND RECORD KEEPING) | 2010-08-13 | Summary not readable | Not stated |
FDA registration and listing
| Registered firm | Role | Products listed | Code | Country |
|---|---|---|---|---|
| Perry Baromedical Corporation | Manufacture Medical Device | Sigma 34, Sigma 36, Sigma ICON 30, Sigma 40, Ground Monitoring System GMS Accessory | CBF | US |
| Perry Baromedical Corporation | Manufacture Medical Device | Sigma Elite 34, 36, and 40, EMR (Electronic Medical Records) Integration Kit | CBF | US |
| Perry Baromedical Corporation | Manufacture Medical Device | Sigma MP | CBF | US |
| Perry Baromedical Corporation | Manufacture Medical Device | Sigma II | CBF | US |
| Perry Baromedical Corporation | Manufacture Medical Device | Sigma 40 II, Sigma Plus/ II | CBF | US |
| Perry Baromedical Corporation | Manufacture Medical Device | Sigma Plus | CBF | US |
| Perry Baromedical Corporation | Manufacture Medical Device | Sigma 1 | CBF | US |
| Perry Baromedical Corporation | Manufacture Medical Device | Bara-Med | CBF | US |
| Perry Baromedical Corporation | Manufacture Medical Device | Bara-Med | CBF | US |
| Perry Baromedical Corporation | Manufacture Medical Device | OSCAR | CBF | US |
What Perry Baromedical says about FDA, checked
- Does not match “'Perry Baromedical's Hyperbaric Systems are FDA Cleared for over 60 years'” Site-wide banner on every product page. The 510(k) program dates from the Medical Device Amendments of May 28, 1976 (stated in every clearance letter). Perry's own history says the Perry Baromedical division was formed in 1979. The earliest hyperbaric chamber 510(k) held by Perry in openFDA is K862198, decided 1986-11-12, about 40 years ago; the oldest K-number Perry lists at all (K832127, held by Nautilus) is from 1983. source, for the claim 'Perry Baromedical's Hyperbaric Systems are FDA Cleared for...
- Matches “'Hyperbaric Oxygen Chambers are United States Food and Drug Administration (FDA) Class II devices and are controlled by federal law.'” About page. K072427 summary: 'Device Class II', product code CBF, 21 CFR 868.5470. source, for the claim 'Hyperbaric Oxygen Chambers are United States Food and Drug...
- Does not match “'All Perry Baromedical Equipment is FDA Class B Medical Device Designed for Commercial Installation.'” Used / Refurbished Chambers page. FDA has no 'Class B'. Perry's own 510(k) summary lists 'Device Class II'. 'Class B' is the NFPA 99 hyperbaric chamber category for single-occupant chambers (Pan-America's 510(k) also calls its monoplace 'Class B'), not an FDA class. source, for the claim 'All Perry Baromedical Equipment is FDA Class B Medical...
- Matches “'Perry Baromedical is a registered medical device manufacturer.'” About page. Active FDA registration FEI 1036464, establishment type 'Manufacture Medical Device', Riviera Beach FL, with 10 CBF listings. source, for the claim 'Perry Baromedical is a registered medical device...
- Matches “SIGMA Series monoplace: 'maximum operational pressures of 3 ATA or 30 psig'” Product advisory page. K072427: 'at pressures not exceeding 3 ATA'. source, for the claim SIGMA Series monoplace: 'maximum operational pressures of 3...
Certifications claimed, checked
- Certificate seen ISO 13485:2016 BSI certificate FM 703045 to Perry Baromedical Corporation, scope 'Design, Development, Manufacture, Service and Installation of Hyperbaric Chambers', effective 2025-03-31, expiry 2028-03-30, both Riviera Beach sites. Read from PDF on brand site; not cross-checked in BSI online directory. source, for the certification ISO 13485:2016
- Certificate seen MDSAP (ISO 13485 plus USA 21 CFR 820, 803, 806, 807; Canada, Japan, Australia) BSI certificate MDSAP 678472, effective 2025-11-21, expiry 2028-03-30. Read from PDF on brand site. source, for the certification MDSAP (ISO 13485 plus USA 21 CFR 820, 803, 806, 807;...
- Certificate seen CE Mark, Pressure Equipment Directive BSI (Notified Body 2797) EU-Type Examination certificate CE 512611 for SIGMA 34, 36 and 40, PED 2014/68/EU Module B, PS = 2.34 bar g, expiry 2027-09-03. The companion Module D production certificate CE 512612 on the site shows expiry 2026-01-31, already past; no renewal was found on the site. PED is pressure-vessel conformity, not medical device CE. source, for the certification CE Mark, Pressure Equipment Directive
- Claim only CE Mark, Medical Device Directive Linked 'Manufacturer Self-Declaration ... NB Letter Extension MDD Compliance' PDF is an image with no text layer; not read. source, for the certification CE Mark, Medical Device Directive
- Certificate seen ASME Certificate of Authorization ASME certificate 26722, Perry Baromedical Corporation, scope 'Manufacture of pressure vessels' ('does not cover welding, brazing or fusing'), authorized 2025-11-18, expires 2028-11-18. source, for the certification ASME Certificate of Authorization
- Claim only ASME PVHO-1 design ('meet or exceed current requirements of ASME, PVHO-1, NFPA-99') PVHO-1 design is stated in Perry's own 510(k) summaries (K072427 cites PVHO-1 2002 edition). No independent PVHO certificate exists as such; about page cites 'ASME/PVHO-2' (the in-service standard). source, for the certification ASME PVHO-1 design ('meet or exceed current requirements of...
- Certificate seen Electrical safety ANSI/AAMI ES60601-1 and CAN/CSA C22.2 No. 60601-1 (power module) SGS North America certificate SGSNA/25/SUW/00131X for Sigma and Sigma Elite power module D-903617, effective 17 February 2026. source, for the certification Electrical safety ANSI/AAMI ES60601-1 and CAN/CSA C22.2 No....
- Claim only National Board of Boiler and Pressure Vessel Inspectors registration NBBI PDF dated 2015 linked; not opened. source, for the certification National Board of Boiler and Pressure Vessel Inspectors...
Perry Baromedical reviews: what buyers report
No Trustpilot, Amazon or BBB rating was found for Perry Baromedical.
Repeated complaints
No complaint was reported by more than one source.
Repeated praise
No praise was repeated across sources.
Perry Baromedical on Reddit
- Automated dive/surface HBOT system? Question for techs.. r/r/Hyperbaric, 2023-04-04, positiveA technician said the Perry Elite is the only automated chamber they knew of and likely very expensive, and that the manual Perry chambers they work with take little effort to run while allowing quick intervention.
- Comment thread in r/HBOT on where to buy HBOT accessories r/r/HBOT, 2025-07-06, negativeA user said HBOT-labelled accessories they found from Perry Baromedical were quite expensive.
- Comment thread in r/Hyperbaric on home-use chambers in the US r/r/Hyperbaric, 2022-08-08, neutralA hyperbaric clinician said Perry chambers are 100% oxygen chambers that now also offer flow-through options.
- Protocols for long covid symptoms? r/HBOT, 2025-07-31, neutralOne long covid patient reports private 2.0 ATA sessions without a mask in a Perry clear acrylic chamber at a clinic in Quebec, running 1.25 to 1.5 hours.
- multiplace space r/HBOT, 2025-07-23, neutralOne user says Perry and Sechrist are the two FDA approved makers of fully see through acrylic chambers and that facilities using them should be able to offer a screen to watch during treatment.
Claims that did not match the record
- Regulatory “'Perry Baromedical's Hyperbaric Systems are FDA Cleared for over 60 years'”Record: 510(k) clearance began after May 28, 1976. Perry's hyperbaric division dates from 1979 (its own history page) and its earliest chamber 510(k) in openFDA is K862198 (1986-11-12), about 40 years. source, for the record against 'Perry Baromedical's Hyperbaric Systems are FDA Cleared for...
- Regulatory “'All Perry Baromedical Equipment is FDA Class B Medical Device'”Record: Perry's 510(k) summary K072427 lists 'Device Class II'. FDA device classes are I, II and III; 'Class B' is an NFPA 99 chamber category. source, for the record against 'All Perry Baromedical Equipment is FDA Class B Medical...
Recalls, safety reports and lawsuits
| Type | Date | What the record says |
|---|---|---|
| Recall, none found | Not stated | No recall in openFDA naming Perry Baromedical; the only 3 CBF recall records are Sechrist (2) and Baro-Therapies (1). source, for the Recall, none found |
| FDA adverse event report | 2025-12-05 (received) | MAUDE 23728558, 23728562, 23728616 (three reports, same facility, events of 2025-05-19 and 2025-05-21): chamber failed to pressurize and treatment was aborted. The facility found that after Perry replaced the gas exchange panels, 'PERRY DID PUT THE LINES IN BACKWARDS, THE AIRLINE WAS ATTACHED TO THE OXYGEN, AND THE OXYGEN WAS ATTACHED TO THE AIR', so patients treated that Monday and Tuesday 'WERE PRESSURIZED ON AIR INSTEAD OF OXYGEN'. Perry sent a technician and corrected the installation error. No patient harm reported. source, for the FDA adverse event report of 2025-12-05 (received) |
| FDA adverse event report | 2012-05-01 (received) | MAUDE MW5025262 (Perry Sigma II): chamber ascended slower than normal; Perry's technician guided a needle valve adjustment by phone and rates were retested within spec. No ill effects. source, for the FDA adverse event report of 2012-05-01 (received) |
| FDA adverse event report | 2004-08-14 (received) | MAUDE 1036464-2004-00001 (Sigma MP-8): malfunction report filed by Perry; no event text published. source, for the FDA adverse event report of 2004-08-14 (received) |
| FDA adverse event report | 2002-08-06 (received) | MAUDE 1036464-2002-00002 (Sigma MP 84 in 6 ATA): fire suppression valve did not operate on first attempt during the required annual NFPA test; no patients present. source, for the FDA adverse event report of 2002-08-06 (received) |
| FDA adverse event report | 2002-06-12 (received) | MAUDE 1036464-2002-00001, filed by Perry as a death report (Sigma II-4): a doctor connected the chamber oxygen supply at 30 lpm to the exhaust connector of a manual resuscitator on an intubated trauma patient; the chamber door was open and the chamber was not pressurized. Perry filed it while noting the doctor did not consider it device related. source, for the FDA adverse event report of 2002-06-12 (received) |
| FDA adverse event report | 1994-12-19 (received) | MAUDE 9943: sudden drop in main pressure and increase inside the chamber 'UP TO 3 DSIG IN 10-15 SECONDS' (as written) with a loud 'burst' on chamber start; patient reported ear buzzing and headache. source, for the FDA adverse event report of 1994-12-19 (received) |
| FDA adverse event report | 2016-10-18 (received) | Related brand: MAUDE 6036511 (Bara-Med, then an ETC product, before Perry's 2019 acquisition): door handle broke and patient was trapped about 20 minutes. source, for the FDA adverse event report of 2016-10-18 (received) |
Who sells Perry Baromedical
- Company
- Perry Baromedical Corporation
- Address on record
- 3595 Fiscal Ct, Riviera Beach, Florida 33404 USA (website); certificates also list 3750 Prospect Avenue, Riviera Beach, FL 33404
- Founded
- Perry Baromedical division formed 1979; renamed Perry Baromedical Corporation 1989; corporate roots to Perry Submarine Builders, 1956 (company history page)
- Owner or parent
- '1992 Mr. Ty Merritt sold Perry Baromedical Corporation to Adatif International of Montreal, Canada, owned by Mr. Kerrigan Turner, the current owner' (company history page; not independently verified)
- Customer support
- US manufacturer; 800-741-4376; field service, annual maintenance and emergency service programs
Sources: 1, company record2, company record3, company record4, company record
Perry Baromedical: common questions
Is Perry Baromedical FDA cleared?
Holds an FDA 510(k) for its device, per openFDA records checked on 11 November 2026. K072427, held by Perry Baromedical Corp., clears SIGMA SERIES HYPERBARIC CHAMBER for: 'The SIGMA Elite 34, 36 and 40 Monoplace Hyperbaric Chambers are intended for use for the following clinical medical conditions in accordance with guidelines established by. There are 11 clearances on record in total; each is listed on this page. 2 FDA claims the brand makes do not match the record; they are quoted below.
Is Perry Baromedical legit?
Perry Baromedical is sold by Perry Baromedical Corporation. On the archive's documentation rule it scores 4 of 5 (well documented), and its customer record is 1 of 3 (weak customer record). 2 of its FDA, certification, performance or safety claims did not match the record. A score measures how well the seller backs up its claims, not whether the therapy works.
What do Perry Baromedical reviews and Reddit threads say?
The research read 5 Reddit threads about the brand, each linked on this page.
What pressure do Perry Baromedical chambers reach?
Perry Baromedical sells hard-shell chambers. The highest pressure it advertises is about 3 ATA. Its FDA 510(k) clears up to about 3 ATA.
Has Perry Baromedical had a recall or safety report?
The records hold 7 FDA adverse event reports, each summarised and linked in the safety section. An adverse event report is an allegation filed with FDA; on its own it does not prove the device caused the event.
How these scores work
Documentation score, 5 points
One point each for: an FDA 510(k) that names the chamber; an advertised pressure no higher than the cleared pressure; ASME PVHO-1 stated in an FDA filing or shown by certificate; an FDA registration on record; no FDA, certification, pressure or safety claim contradicted by a record. Fabric chambers fall outside PVHO-1, so a soft chamber cannot earn that point.
5 is fully documented, 4 well documented, 3 partly documented, 0 to 2 thinly documented.
Customer record, 3 points
One point each for: rated 4.0 or better on a review site with 50 or more reviews; a Better Business Bureau grade of A- or better; no single complaint reported by three or more independent buyers or sites. With too few reviews, the record says “not enough reviews to rate” instead of guessing.
Neither score says whether the therapy works. That is what the evidence pages measure.
What could not be verified
- Certificates read from PDFs on the brand's site, not cross-checked in BSI, ASME or SGS online directories.
- CE 512612 (PED Module D) expired 2026-01-31 per its face; renewal not published.
- Scanned 510(k) PDFs K990927, K974868, K983648 read by OCR; numeric pressures not legible in K990927 and K974868.
- Reddit, BBB, Google reviews, hyperbaric professional forums (e.g. UHMS, Baromedical forums) not checked: web search budget exhausted.
- FDA warning letter database not searched.
- No prices published (quote basis); warranty stated only for Sigma 34 (one year).
- MAUDE 2004 Sigma MP-8 report has no narrative text.
- Reddit: threads added on 2026-11-11 from the Arctic Shift archive (a public Reddit mirror), which supersedes any earlier note here that Reddit could not be read. Usernames are not in the archive extract, so independent-user counts are judged from content. Mentions come from hyperbaric staff, not consumer owners.
No seller paid to be listed or rated. For what hyperbaric oxygen has been measured to do in people, read the hyperbaric oxygen evidence.