Red light beds and pods · researched 11 November 2026
NovoTHOR review: FDA status, lab tests and what buyers report
Every fact below links to the page or record it came from. NovoTHOR devices were checked against FDA's own databases, brightness claims against independent optical tests, and buyer reports on Reddit, Trustpilot, BBB and Amazon. A second researcher re-checked the record, 36 items, and corrected or removed what did not hold.
- Company
- THOR Photomedicine Ltd (UK owner/operator and specification developer); THOR Photomedicine Inc. (US manufacturer of record)
- FDA status
- FDA registered and listed only, not cleared
- Prices found
- Not published
- Website
- www.novothor.com
Documentation score
4 of 5
Well documented
- Wavelengths published
- Brightness published with its distance
- Optical test on file
- Traceable at FDA
- No material claim contradicted
Customer record
Not rated
Not enough reviews to rate
- Rated 4.0 or better on 50 or more reviews
- BBB rating A- or better
- No complaint repeated across 3 or more sources
Too few public reviews were found to rate this seller.
NovoTHOR devices on record
| Model | Type | Wavelengths (nm) | Brightness claimed | Price | Warranty |
|---|---|---|---|---|---|
| NovoTHOR (Standard; FDA recall records name Gen 3.0 Reg S2188 and Reg PRX S2189) | bed | 660, 850 | Not published | Not published | 5 years |
| NovoTHOR XL (FDA recall records name S2190) | bed | 660, 850 | Not published | Not published | 5 years |
Is NovoTHOR FDA cleared?
| 510(k) | Held by | Cleared device | Decision | Cleared for | Code |
|---|---|---|---|---|---|
| K033923 | THOR International Ltd, Amersham, UK (per the 510(k) summary; key contact James Carroll). The openFDA 510(k) record shows applicant 'Thor Intl.' at 12101 Cullen Blvd, Houston, TX, contact M. Joyce Heinrich. | THOR DDII IR Lamp System (openFDA record spells it 'TH0R DDII IR LAMP SYSTEM') | 2004-03-17 | The THOR IR Lamp System is intended to emit energy in the visible and near infrared spectrum to provide topical heating for the purpose of elevating tissue temperature for the temporary relief of minor muscle and joint pain and stiffness, minor arthritis pain, or muscle spasm; the temporary increase in local blood circulation; and / or the temporary relaxation of muscle. (read from scanned summary; the 'and / or' rendered as 'and I or' in OCR) | ILY |
FDA registration and listing
| Registered firm | Role | Products listed | Code | Country |
|---|---|---|---|---|
| THOR PHOTOMEDICINE INC. | Manufacture Medical Device (record also flags initial importer = Y) | NOVOTHOR Whole Body Light Pod, NovoTHOR XL Whole Body Light Pod, NovoTHOR, NovoTHOR Standard | ILY (Lamp, Infrared, Therapeutic Heating; Class II, 21 CFR 890.5500, 510(k) exempt) | US (Randolph, VT) |
| THOR Photomedicine Ltd | Develop Specifications But Do Not Manufacture At This Facility | NOVOTHOR Whole Body Light Pod, NovoTHOR XL Whole Body Light Pod, NovoTHOR, NovoTHOR Standard | ILY | GB (Amersham, Buckinghamshire) |
What NovoTHOR says about FDA, checked
- Matches “NovoTHOR is approved or cleared as a medical device in over 30 countries” novothor.com home page and /us/ page. Not contradicted as worded, but for the US there is no NovoTHOR 510(k) clearance: the device is registered and listed under product code ILY, which 21 CFR 890.5500 makes 510(k) exempt. US readers should not read this as FDA clearance. source, for the claim NovoTHOR is approved or cleared as a medical device in over...
- Matches “NovoTHOR is intended to be used for the temporary relief of minor muscle and joint pain and stiffness, minor arthritis pain, or muscle spasm; the temporary increase in local blood circulation; and/or the temporary relaxation of muscle.” novothor.com home page. Matches the intended use THOR gave FDA in the 2025 recall record for NovoTHOR S2188 and the wording of THOR's older K033923 clearance. The exemption in 21 CFR 890.5500 covers infrared lamps intended for topical heating, subject to 21 CFR 890.9 limits. source, for the claim NovoTHOR is intended to be used for the temporary relief of...
- Matches “Designed and manufactured by THOR in the USA” novothor.com home page and technology page. FDA lists THOR Photomedicine Inc., Randolph, VT as the manufacturing establishment for all NovoTHOR names; the UK entity is listed as specification developer only. source, for the claim Designed and manufactured by THOR in the USA
Has NovoTHOR been lab tested?
| Tester | Instrument | Model and distance | Result | Paid or supplied by | Matches brand claim |
|---|---|---|---|---|---|
| LightLab International Allentown, LLC (Allentown, PA), report LLIA002781-001 on page 1, LLIA002780-001 on pages 2 and 32025-10-20 | Gigahertz-Optik BTS2048-VL-TEC spectral irradiance meter (calibrated 4/17/2025) | NovoTHOR XL I041, 0 in | 300 to 1050 nm, 20 points at the clear bed surface, lid open, all channels full: average 29.76 mW/cm2, stated maximum 32.04, minimum 26.36. Central point over 20 minutes stayed between 31.81 and 33.21 mW/cm2. Note: the grid table includes a 32.95 reading, above the stated maximum, and the report number differs between page 1 and pages 2 to 3. Only the bottom surface was measured. The arithmetic mean of the 20 printed grid values is 30.13 mW/cm2, not the stated 29.76. | Prepared for Spectra Red Light (a competing red light bed maker); unit measured on-site at Spectra's headquarters in Harrisburg, PA; published on Spectra's comparison page | Not comparable |
- Unverified “NovoTHOR delivered more than 4x the power of a Theralight 360 in testing performed by the Uniformed Services University (Hollander M.E., Hagen J., Givens M., Metzger E., Anders J.J., 'Best Practices for Assessing and Validating Photobiomodulation Therapy Devices', award HU00011920056)” No publication with this title or author set was found in PubMed or Crossref, so the method, instrument, model versions and metric (total power vs irradiance) could not be checked. The only independent-lab numbers found (both commissioned by competitor Spectra) are 29.76 mW/cm2 average for a NovoTHOR XL and 13.47 mW/cm2 for a TheraLight 360 Plus, about 2.2x on irradiance, which is a different metric from total power. source, for the claim NovoTHOR delivered more than 4x the power of a Theralight...
- Unverified “We use a laboratory grade spectrophotometer to measure light output through a 24 hour burn in procedure” Internal QC claim; no burn-in data or reports published. source, for the claim We use a laboratory grade spectrophotometer to measure...
- Not supported “5 independent clinical studies came to the same conclusion about the effectiveness of the NovoTHOR; NovoTHOR is the only light bed with independently researched and published clinical results” The page does not name the five studies. Four published NovoTHOR studies list THOR's owner James Carroll as co-author with declared conflicts (PMIDs 35222905, 36359198, 36369323, 38356644), and 36369323 states the study was supported by James Carroll. Independent NovoTHOR studies exist (PMIDs 37753995, 36006085, 33345040), but 33345040 found no significant effect on CK or IL-6, so they did not all reach the same conclusion. source, for the claim 5 independent clinical studies came to the same conclusion...
- Unverified “Manufacturer-supplied NovoTHOR parameters reported in studies: 0.028 W/cm2 irradiance, 2880 LEDs (Navarro-Ledesma 2023, table headed NovoTHOR / NovoTHOR XL); 0.012 W/cm2 per wavelength, 1200 + 1200 LEDs, 'provided by the device manufacturer' (Rentz 2022); 17 mW/cm2, 2,800 LEDs (Ghigiarelli 2020)” Figures differ by study and generation and are not measured by an independent lab. The 28 mW/cm2 figure is close to the 29.76 mW/cm2 average the Spectra-commissioned test found on an XL bed surface. source, for the claim Manufacturer-supplied NovoTHOR parameters reported in...
Certifications claimed, checked
- Claim only BS EN ISO 13485 (quality management) Listed as a standard the product is 'built to'; no certificate number or notified body shown. source, for the certification BS EN ISO 13485 (quality management)
- Claim only IEC 60601-1, IEC 60601-1-2, IEC 60601-1-6, IEC 60601-2-57 Listed as standards the product is built to; no test report or CB certificate published. source, for the certification IEC 60601-1, IEC 60601-1-2, IEC 60601-1-6, IEC 60601-2-57
- Claim only IEC 62471 photobiological safety; IEC 62304; ISO 10993-1; ISO 14971; IEC 62366; ISO 15223-1 Listed only; no reports published. source, for the certification IEC 62471 photobiological safety; IEC 62304; ISO 10993-1;...
- Claim only CE marked, 'independantly tested', made to GMP standards No CE certificate or notified body number shown. source, for the certification CE marked, 'independantly tested', made to GMP standards
- Claim only RoHS compliant Statement only. source, for the certification RoHS compliant
NovoTHOR reviews: what buyers report
No Trustpilot, Amazon or BBB rating was found for NovoTHOR.
Repeated complaints
No complaint was reported by more than one source.
Repeated praise
No praise was repeated across sources.
NovoTHOR on Reddit
- My youtube review of Novothor light bed..hint I am not a fan r/redlighttherapy, 2024-10-16, negativeA reviewer who says he consults in the photobiomodulation industry posted a negative YouTube review of the NovoTHOR bed. He has an industry role, so this is not an independent buyer report.
Independent reviewers, forums and video
- Light Therapy Insiders (Bart Wolbers) Reviews 12 THOR studies; calls NovoTHOR the 'gold standard' red light bed and recommends it for buyers with the means, but notes one NovoTHOR inflammation study and one THOR running study were null, and that the article itself is inconsistent on NovoTHOR LED count (2,000 vs 2,800). No NovoTHOR price given. Author links to his review of the THOR CEO's course he took; links to novothor.com and thorlaser.com carry no affiliate parameters.
Claims that did not match the record
- Marketing “5 independent clinical studies came to the same conclusion about the effectiveness of the NovoTHOR”Record: At least four published NovoTHOR trials are co-authored and in one case funded by THOR's owner (declared conflicts), and an independent NovoTHOR randomized trial (Ghigiarelli 2020) found no significant difference in CK or IL-6 versus control. source, for the record against 5 independent clinical studies came to the same conclusion...
Recalls, safety reports and lawsuits
| Type | Date | What the record says |
|---|---|---|
| Recall | 2022-09-13 | Class II recall Z-0453-2024 to Z-0456-2024 (event 93344): NovoTHOR Gen 2.0 (S1176), Gen 2.0 XL (S1177), Gen 2.5 Reg (S2183), Gen 2.5 XL (S2184); ball stud failure lets a gas strut detach from the canopy, making it difficult to lift. 77 units total. Root cause: device design. Status open. source, for the Recall of 2022-09-13 |
| Recall | 2023-11-20 | Class II recall Z-0972-2024 (event 93723): NovoTHOR Gen 3.0 S2188 Reg, S2189 Reg PRX, S2190 XL; a canopy ball stud may fail, potential injury when opening or closing; 61 units (41 US, 20 outside US). Root cause: component design/selection. Status open. source, for the Recall of 2023-11-20 |
| Recall | 2025-07-24 | Class II recall Z-2416-2025 to Z-2419-2025 (event 97297): NovoTHOR S2188, XL S2190, Reg PRX S2189 and S2186; a failed welded nut can shear off so a gas strut detaches from the canopy; 138 units total; fix is four high tensile bolts fitted by THOR. Root cause: process control. Status open. source, for the Recall of 2025-07-24 |
| FDA adverse event report | 2025-02-27 | MDR (malfunction), NovoTHOR XL S2190: gas struts let the lid close slowly by itself when left open; no harm reported. source, for the FDA adverse event report of 2025-02-27 |
| FDA adverse event report | 2026-08-04 | MDR 3003899624-2026-00001 (injury), NovoTHOR XL S2190, UK clinic: patient with unstable eczema reported heat and skin irritation then a flare needing oral steroids after sessions; THOR says use was outside indications and causation could not be determined. source, for the FDA adverse event report of 2026-08-04 |
| FDA adverse event report | 2023-12-06 | 22 other THOR MDRs (2023 to 2025) concern THOR laser and LED probes (LX2 system), not NovoTHOR, including probes running hot and two reports of burn marks on patients. source, for the FDA adverse event report of 2023-12-06 |
Who sells NovoTHOR
- Company
- THOR Photomedicine Ltd (UK owner/operator and specification developer); THOR Photomedicine Inc. (US manufacturer of record)
- Address on record
- Units 1 & 2 Anglo Office Park, Amersham, Buckinghamshire, UK; US manufacturing establishment 296 Beanville Road, Suite B, Randolph, VT
- Founded
- THOR states it has been in light therapy since 1991 (company, not the NovoTHOR product); NovoTHOR FDA listings created 2017-11-24
- Owner or parent
- THOR Photomedicine Ltd. Published conflict of interest statements say James D. Carroll (CEO) is the owner of THOR Photomedicine.
- Customer support
- +1 877 355 3151 (USA & Canada, per novothor.com footer); FDA US agent of record: Jennifer Anderson, Millersville, MD
Sources: 1, company record2, company record3, company record4, company record5, company record
NovoTHOR: common questions
Is NovoTHOR FDA cleared?
FDA registered and listed only, not cleared, per openFDA records checked on 11 November 2026. Registration and listing is a filing by the company. It is not an FDA review of whether the device is safe or works, and it is not a clearance.
Is NovoTHOR legit?
On the archive's documentation rule it scores 4 of 5 (well documented), and its customer record is not rated, because there are not enough reviews. None of its FDA, certification, performance or safety claims was contradicted by a record. A score measures how well the seller backs up its claims, not whether the therapy works.
What do NovoTHOR reviews and Reddit threads say?
The research read 1 Reddit thread about the brand, each linked on this page.
What wavelengths do NovoTHOR devices use?
Across its current devices the brand lists 2 distinct wavelengths: 660 nm and 850 nm. Listed wavelengths are the seller's figures; where an independent test checked the peaks, it is shown in the lab test table.
Has anyone lab tested NovoTHOR?
One optical test is on record. LightLab International Allentown, LLC (Allentown, PA), report LLIA002781-001 on measured the NovoTHOR XL I041 at 0 inches: 300 to 1050 nm, 20 points at the clear bed surface, lid open, all channels full: average 29.76 mW/cm2, stated maximum 32.04, minimum 26.36. Paid for or supplied by: Prepared for Spectra Red Light (a competing red light bed maker); unit measured.
Has NovoTHOR had a recall or safety report?
The records hold 3 recalls and 3 FDA adverse event reports, each summarised and linked in the safety section. An adverse event report is an allegation filed with FDA; on its own it does not prove the device caused the event.
How these scores work
Documentation score, 5 points
One point each for: wavelengths published; brightness published with the distance it was measured at; a spectroradiometer or integrating sphere test of a current device on file; traceable at FDA through a 510(k) or a registration and listing; no FDA, certification, performance or safety claim contradicted by a record or by a test at the seller's own distance.
5 is fully documented, 4 well documented, 3 partly documented, 0 to 2 thinly documented.
Customer record, 3 points
One point each for: rated 4.0 or better on a review site with 50 or more reviews; a Better Business Bureau grade of A- or better; no single complaint reported by three or more independent buyers or sites. With too few reviews, the record says “not enough reviews to rate” instead of guessing.
Neither score says whether the therapy works. That is what the evidence pages measure.
What could not be verified
- NovoTHOR does not publish an irradiance figure, LED count or price on its site.
- Competitor Spectra lists NovoTHOR XL at $130,000 on one page and NovoTHOR at $150,000 on another; THOR's own pricing not found.
- USU 'Best Practices for Assessing and Validating Photobiomodulation Therapy Devices' study behind the '4x TheraLight 360' claim could not be located.
- Reddit and Amazon could not be read (Reddit 403/429 and bot challenge; Amazon returned a stub page). Trustpilot has an unclaimed novothor.com profile with 0 reviews. WebSearch budget was exhausted, so YouTube reviewers and other forums were not searched.
- BBB directory API returned no profile for THOR Photomedicine, NovoTHOR or Thor Laser.
- The FDA record flags THOR Photomedicine Inc. as an initial importer as well as manufacturer; which components are imported was not determined.
- The five studies behind the '5 independent clinical studies' claim are not named on the page.
- Reddit threads added on 2026-11-11 from the Arctic Shift Reddit archive; Reddit itself blocks automated reading.
No seller paid to be listed or rated. For what red light has been measured to do in people, read the red light evidence.