Home red light devices · researched 13 November 2026
Zemits review: FDA status, lab tests and what buyers report
Every fact below links to the page or record it came from. Zemits devices were checked against FDA's own databases, brightness claims against independent optical tests, and buyer reports on Reddit, Trustpilot, BBB and Amazon. A second researcher re-checked the record, 22 items, and corrected or removed what did not hold.
- Company
- Advance-Esthetic LLC (operates the Zemits brand)
- FDA status
- Listed under another company's 510(k)
- Prices found
- $108 to $990
- Website
- zemits.com
Documentation score
2 of 5
Thinly documented
- Wavelengths published
- Brightness published with its distance
- Optical test on file
- Traceable at FDA
- No material claim contradicted
Customer record
Not rated
Not enough reviews to rate
- Rated 4.0 or better on 50 or more reviews
- BBB rating A- or better
- No complaint repeated across 3 or more sources
Too few public reviews were found to rate this seller.
Zemits devices on record
| Model | Type | Wavelengths (nm) | Brightness claimed | Price | Warranty |
|---|---|---|---|---|---|
| Zemits VivaLumix | other | 415, 630, 850 | Not published | $990 | 36-Month Warranty |
| Zemits MaiSkin | mask | 630, 465, 530, 850 | Not published | $299 | Not stated |
| Zemits EcliPure (neck LED) | other | 620, 460, 850 | Not published | $259 | 1-Year Warranty |
| Zemits UltraGlow | handheld | 640, 550, 430 | Not published | $107.5 | Not stated |
Is Zemits FDA cleared?
| 510(k) | Held by | Cleared device | Decision | Cleared for | Code |
|---|---|---|---|---|---|
| K243555 | Shenzhen Eyco Technology Co., Ltd. | LED light therapy mask (E43, E32, E49B, E49C, E100B, E100C, E103B, E104B, E106A, E108A) | 2025-02-05 | Mode 1 (Red + Infrared light): treatment of full face wrinkles. Mode 2 (Blue light): Treatment of mild to moderate inflammatory acne. Mode 3 (Mixed light): Treatment of mild to moderate inflammatory acne. | OLP |
| K243423 | Shenzhen Rainbow Technology Co., Ltd. | LED Light Therapy Mask (Model(s): RB-008, RB-030, RB-081, RB-008G, RB-008GB, RB-008J, RB-008JB) | 2025-01-28 | - Red+Infrared light: Treatment of full-face wrinkles. - Red light: Treatment of full-face wrinkles. - Infrared light: Provide topical heating for the purpose of elevating tissue temperature; arthritis and muscle spasm; relieving stiffness; promoting the relaxation of muscle tissue; and to temporarily increase local blood circulation. - Blue light: Treatment of mild to moderate inflammatory acne. - Red+Blue light: Treatment of mild to moderate inflammatory acne. The device is intended to use LED light for the treatment of wrinkles and mild to moderate acne for adults in home healthcare environment. | OHS |
| K162098 | Li-Tek Electronic Technology Corporation | LED Phototherapy Device | 2017-01-30 | The red light is intended for the treatment of periorbital wrinkles, and the blue light is intended for the treatment of the mild to moderate inflammatory acne. | OLP |
| K200751 | Shangdong Huamei Technology Co., Ltd. | Photodynamic Therapy (PDT) Equipment | 2020-05-21 | The Photodynamic Therapy (PDT) Equipment use of the red, blue and infrared regions of the spectrum is intended to emit energy to treat dermatological conditions. The blue light (415nm wavelength) is generally indicated to treat dermatological conditions and specifically indicated to treat moderate inflammatory acne vulgaris. The red light (630nm wavelength) is generally indicated to treatment of superficial, benign vascular, and pigmented lesions. The infrared light (835nm wavelength) is generally use for the temporary relief of minor muscle and joint pain, arthritis and muscle spasm; relieving stiffness; promoting the relaxation of muscle tissue; and to temporarily increase local blood circulation where applied. | GEX |
FDA registration and listing
| Registered firm | Role | Products listed | Code | Country |
|---|---|---|---|---|
| ADVANCE-ESTHETIC LLC | Complaint File Establishment per 21 CFR 820.198 | Zemits VivaLumix | OHS, OLP (K243555) | US |
| ADVANCE-ESTHETIC LLC | Complaint File Establishment per 21 CFR 820.198 | Zemits MaiSkin | OHS, OLP, ILY (K243423) | US |
| ADVANCE-ESTHETIC LLC | Complaint File Establishment per 21 CFR 820.198; Repack or Relabel Medical Device | Zemits LED | OHS, OLP (K162098); ILY (no K-number) | US |
| ADVANCE-ESTHETIC LLC | Complaint File Establishment per 21 CFR 820.198; Develop Specifications But Do Not Manufacture At This Facility | Zemits Ultraglow (within a list of facial devices) | GFE | US |
| SHENZHEN EYCO TECHNOLOGY CO.,LTD | Manufacture Medical Device | Zemits VivaLumix LED Light Device (among other brands' masks) | OHS, OLP (K243555) | CN |
What Zemits says about FDA, checked
- Unconfirmed “Three FDA-Cleared Wavelengths Engineered with Blue (415 nm), Red (630 nm), and Infrared (850 nm) LEDs” VivaLumix product page. Wavelengths match the K243555 subject device (415/630/850nm), and both Zemits and the holder list VivaLumix under K243555, but the cleared device names are face masks only and the 510(k) summary does not describe a dome device. Clearance attaches to the device, not to wavelengths. source, for the claim Three FDA-Cleared Wavelengths Engineered with Blue (415...
- Unconfirmed “Certification - FDA and CE certified, confirming safety and effectiveness.” VivaLumix product page. Terminology is wrong (FDA clears, it does not certify), but the record does not flatly contradict an FDA status: both Advance-Esthetic and the 510(k) holder Shenzhen Eyco list 'Zemits VivaLumix' under K243555. The open question is that the cleared device names are face masks E43 to E108A and the summary does not describe a dome. CE documentation not published. source, for the claim Certification - FDA and CE certified, confirming safety and...
- Unconfirmed “MaiSkin is FDA cleared. Ask Zemits for the current clearance documentation, official model information, cleared indications, and required labeling before purchase” MaiSkin product page FAQ. Advance-Esthetic lists MaiSkin under K243423 (Shenzhen Rainbow LED masks RB-008 etc.). The cleared modes include red, infrared, blue and red+blue; MaiSkin's green 530nm programs are not among the cleared indications. source, for the claim MaiSkin is FDA cleared. Ask Zemits for the current...
- Does not match “Red & Blue light therapy device, a masterpiece that's both FDA-cleared and endorsed by dermatologists.” EcliPure product page. No openFDA listing or 510(k) names EcliPure under any registrant. source, for the claim Red & Blue light therapy device, a masterpiece that's both...
Has Zemits been lab tested?
No optical test of a current Zemits device was found, from the brand or from anyone else.
- Unverified “INTENSITY Red light: 2.0 to 3.0 mW/cm2, Blue light: 2.0 to 4.0 mW/cm2, Infrared light: 2.0 to 4.0 mW/cm2 (EcliPure)” No test report, instrument or distance provided. These figures are identical to the predicate device K223544 (Guangdong Newdermo LED mask) values tabulated in the K243555 summary; no record links EcliPure to that device. source, for the claim INTENSITY Red light: 2.0 to 3.0 mW/cm2, Blue light: 2.0 to...
- Unverified “FDA-cleared and rigorously tested, VivaLumix provides safe, non-invasive light exposure” No test report published. source, for the claim FDA-cleared and rigorously tested, VivaLumix provides safe,...
Certifications claimed, checked
- Not supported FDA and CE certified (VivaLumix) See brand_fda_claims; CE certificate not published. source, for the certification FDA and CE certified (VivaLumix)
Zemits reviews: what buyers report
No Trustpilot, Amazon or BBB rating was found for Zemits.
Repeated complaints
No complaint was reported by more than one source.
Repeated praise
No praise was repeated across sources.
Zemits on Reddit
No Reddit thread about Zemits could be read for this record.
Claims that did not match the record
- Regulatory “EcliPure is 'FDA-cleared'”Record: No FDA listing or 510(k) names EcliPure. source, for the record against EcliPure is 'FDA-cleared'
Recalls, safety reports and lawsuits
| Type | Date | What the record says |
|---|---|---|
| Recall | 2023-10-09 | Recall Z-0095-2024 (Open, Classified) of MED-810A Zemits NDPrime Laser products (tattoo removal laser, not a red light device): firm failed to comply with laser product performance standards; missing remote interlock connector, safety interlocks, manual reset, beam attenuator, certification, class IV labeling. source, for the Recall of 2023-10-09 |
| FDA adverse event report | 2026-02-10 | MW5183631, injury report, Quidion Lite Pro diode hair-removal laser (not red light): reporter states the laser and related models burned multiple clients. source, for the FDA adverse event report of 2026-02-10 |
| FDA adverse event report | 2025-08-21 | MW5175099, injury report, Quidion laser (not red light): reporter alleges burns and that devices are made in China without real testing. source, for the FDA adverse event report of 2025-08-21 |
| FDA adverse event report | 2024-12-20 | MW5163831, malfunction report, Zemits DermeLuxx Pro hydrodermabrasion machine: repeated suction failures and repairs. source, for the FDA adverse event report of 2024-12-20 |
| FDA adverse event report | 2019-04-09 | MW5085721, malfunction report, Zirra RF cavitation system by Zemits: reporter states they were burned and alleges devices lack 510(k). source, for the FDA adverse event report of 2019-04-09 |
Who sells Zemits
- Company
- Advance-Esthetic LLC (operates the Zemits brand)
- Address on record
- 4101 Ravenswood Rd, Ste 110, Fort Lauderdale, FL 33312, USA
- Owner or parent
- FDA registration 3013397886 (Advance-Esthetic LLC, Fort Lauderdale FL) lists all Zemits-branded devices; recall Z-0095-2024 names Advance-Esthetic LLC with a customer-support@advance-esthetic.us contact. Zemits also lists US showrooms in Carlsbad CA, Dallas TX and New York NY and international sites (zemits.eu and others). Primarily professional esthetician equipment; LED devices are also sold to home customers.
- Customer support
- Sales +1-888-564-5060; Customer Support +1-305-918-1175; info@zemits.com
Sources: 1, company record2, company record3, company record4, company record
Zemits: common questions
Is Zemits FDA cleared?
Listed under another company's 510(k), per openFDA records checked on 13 November 2026. The 510(k) numbers its products are listed under belong to other companies and name differently titled devices, so they are not the brand's own clearance. One FDA claim the brand makes does not match the record; they are quoted below.
Is Zemits legit?
Zemits is sold by Advance-Esthetic LLC (operates the Zemits brand). On the archive's documentation rule it scores 2 of 5 (thinly documented), and its customer record is not rated, because there are not enough reviews. 1 of its FDA, certification, performance or safety claims did not match the record. A score measures how well the seller backs up its claims, not whether the therapy works.
What do Zemits reviews and Reddit threads say?
The research found too few public reviews to summarise. That is stated rather than filled in.
What wavelengths do Zemits devices use?
Across its current devices the brand lists 10 distinct wavelengths: 415 nm, 430 nm, 460 nm, 465 nm, 530 nm, 550 nm, 620 nm, 630 nm, 640 nm and 850 nm. Listed wavelengths are the seller's figures; where an independent test checked the peaks, it is shown in the lab test table.
Has anyone lab tested Zemits?
No spectroradiometer or integrating sphere test of a current device was found, from the brand or anyone else. Brightness figures for this brand are the seller's own.
Has Zemits had a recall or safety report?
The records hold 1 recall and 4 FDA adverse event reports, each summarised and linked in the safety section. An adverse event report is an allegation filed with FDA; on its own it does not prove the device caused the event.
How these scores work
Documentation score, 5 points
One point each for: wavelengths published; brightness published with the distance it was measured at; a spectroradiometer or integrating sphere test of a current device on file; traceable at FDA through a 510(k) or a registration and listing; no FDA, certification, performance or safety claim contradicted by a record or by a test at the seller's own distance.
5 is fully documented, 4 well documented, 3 partly documented, 0 to 2 thinly documented.
Customer record, 3 points
One point each for: rated 4.0 or better on a review site with 50 or more reviews; a Better Business Bureau grade of A- or better; no single complaint reported by three or more independent buyers or sites. With too few reviews, the record says “not enough reviews to rate” instead of guessing.
Neither score says whether the therapy works. That is what the evidence pages measure.
What could not be verified
- WebSearch budget for this run was exhausted before review research, so Reddit, Amazon, BBB, Google, YouTube and esthetician forum searches were not performed; Arctic Shift was not queried. Reviews section is incomplete, not evidence of no reviews.
- No independent lab test found for any Zemits LED device; Light Therapy Insiders site search showed no visible match (script-rendered search, inconclusive).
- FDA warning letters not searched (requires web search).
- LED counts and irradiance for VivaLumix, MaiSkin and UltraGlow not published on product pages.
- Which product the 'Zemits LED' listing (K162098) refers to is unknown.
- Founding year not found; site footer shows 2023 to 2026 copyright.
No seller paid to be listed or rated. For what red light has been measured to do in people, read the red light evidence.