Red light beds and pods · researched 11 November 2026
ARRC LED review: FDA status, lab tests and what buyers report
Every fact below links to the page or record it came from. ARRC LED devices were checked against FDA's own databases, brightness claims against independent optical tests, and buyer reports on Reddit, Trustpilot, BBB and Amazon. A second researcher re-checked the record, 38 items, and corrected or removed what did not hold.
- FDA status
- FDA registered and listed only, not cleared
- Prices found
- $95,000 to $150,000
- Website
- arrcled.com
Documentation score
3 of 5
Partly documented
- Wavelengths published
- Brightness published with its distance
- Optical test on file
- Traceable at FDA
- No material claim contradicted
Customer record
Not rated
Not enough reviews to rate
- Rated 4.0 or better on 50 or more reviews
- BBB rating A- or better
- No complaint repeated across 3 or more sources
Too few public reviews were found to rate this seller.
ARRC LED devices on record
| Model | Type | Wavelengths (nm) | Brightness claimed | Price | Warranty |
|---|---|---|---|---|---|
| The Elysium Device | bed | 530, 633, 660, 810, 850, 940 | 150 mW/cm2, no distance given | $150,000 | 5-year bumper to bumper (brand claim) |
| ATP RFQ | bed | Not listed | Not published | $95,000 | 5-year bumper-to-bumper (homepage claim) |
| MAX RFQ | bed | Not listed | Not published | Not published | Not stated |
Is ARRC LED FDA cleared?
No 510(k) clearance was found for ARRC LED or its devices in openFDA.
FDA registration and listing
| Registered firm | Role | Products listed | Code | Country |
|---|---|---|---|---|
| Semi-Kinetics, Inc. OBO SK Global Trading Inc. (owner/operator SK Global Trading Inc) | Manufacture Medical Device | MONICOR ROFES, ARRC PEMF, ARRC PHOTOBIOMODULATION, ARRC SCAN, ARRC FREQENCY | HCC (Device, Biofeedback, 21 CFR 882.5050, Class 2; listing created 2022-06-27) | US |
| Semi-Kinetics, Inc. OBO SK Global Trading Inc. | Manufacture Medical Device for Another Party (Contract Manufacturer) | ILY (Lamp, Infrared, Therapeutic Heating, 21 CFR 890.5500, Class 2; listing created 2021-01-28) | US |
What ARRC LED says about FDA, checked
- Matches “Devices are 'designed, engineered, and built in the U.S.A. in ISO 9001, military, and FDA-compliant facilities'” About page. Partly supported only: an active FDA establishment registration exists for Semi-Kinetics, Inc. OBO SK Global Trading Inc. in Lake Forest, CA. Registration does not show compliance status, inspection results or any clearance. ISO 9001 and 'military' facility claims were not verified. source, for the claim Devices are 'designed, engineered, and built in the U.S.A....
- Does not match “'ARRC LED makes no claims regarding the direct effectiveness of our systems for any condition other than relief from minor aches and pains'” Disclaimer on the Elysium, ATP RFQ and About pages. No 510(k) clearance for any indication, including minor aches and pains, was found in openFDA under applicant or device name ARRC, SK Global or Semi-Kinetics. The only ARRC-named listing is under biofeedback code HCC, not a light or heating code. Under 21 CFR 882.5050 a biofeedback device is exempt from 510(k) only when it is a prescription battery powered device for relaxation training and muscle reeducation; ARRC lists its bed as a 220 V, 30 A device. source, for the claim 'ARRC LED makes no claims regarding the direct...
- Matches “'© 2026 ARRC LED. Not intended to diagnose, treat, cure or prevent any disease.'” Homepage footer. Consistent with the absence of any 510(k) or PMA in openFDA for ARRC. The bed's photobiomodulation function is listed only by name under biofeedback product code HCC. source, for the claim '© 2026 ARRC LED. Not intended to diagnose, treat, cure or...
Has ARRC LED been lab tested?
| Tester | Instrument | Model and distance | Result | Paid or supplied by | Matches brand claim |
|---|---|---|---|---|---|
| Hollander, Hagen, Givens, Metzger, Anders, Wagner, Isaacson, Pasquina, Hager (The Geneva Foundation, The Ohio State University, Air Force Research Laboratory 711th HPW, Uniformed Services University), poster 'Spectroradiometric Analyses of Commercial Photobiomodulation Technologies', MHSRS 20242024 | GL SPECTIS 5.0 Touch VIS-IR (380 to 1050 nm, NIST traceable calibration, radiometric accuracy within 4%) | 'ARRC LED' bed, model not named. Wavelengths reported by the maker at the time: 635, 660, 850, 890, 950 nm; measured peaks 636, 667, 817, 860, 951 nm. ARRC's green LEDs were not measured. | 20-minute session average 32.95 mW/cm2; horizontal axis average top canopy 36.48 mW/cm2, bottom canopy 33.05 mW/cm2. Poster lists ARRC 'Reported: 76 mW/cm2'. NovoTHOR XL averaged 23.24 and TheraLight 7.42 in the same study. | Project sponsored by the Uniformed Services University, award HU00011920056. The poster does not say who supplied the ARRC bed or where it was measured. Co-author Dr. Joshua Hagen also appears in a testimonial on ARRC's About page ('I massively recommend ARRC LED'). | Not comparable |
| LightLab International Allentown, LLC (report LLIA002780-001-R01, signed by Michael L. Grather)2025-09-30 | Gigahertz-Optik BTS2048-VL-TEC Spectral Irradiance Meter System, calibrated 4/17/2025 (certificate 2541045) | 'AARC RFQ Red Light Therapy Bed' (ARRC RFQ; sub-model ATP or MAX not stated), 0 in | 20 points at the clear bed surface, sensor pointed down, lid open, all channels on full, non-pulsed, 300 to 1050 nm: average 46.35 mW/cm2, minimum 36.96, maximum 53.18. Central point stable at about 44 mW/cm2 over 20 minutes (45.01 at 30 s, 44.01 at 1170 s). Lab note: one line of LEDs in the bed section appeared to be non-functioning. | Prepared for Spectra Red Light (Millerstown, PA), a competing red light bed seller. Measured on site at Hypercharge Clinic, Maple Grove, MN. The lab states it did not select the sample. | Not comparable |
- Verified “'Highest irradiance of every full-body bed tested' by researchers from the Geneva Foundation, Ohio State, AFRL and USU” True within that poster, which measured only three beds: ARRC 32.95, NovoTHOR XL 23.24, TheraLight 7.42 mW/cm2 average. source, for the claim 'Highest irradiance of every full-body bed tested' by...
- Not supported “'Research from The Geneva Foundation and OSU (2024) verified that our technology outperformed all other full-body systems in irradiance testing'” The poster compared ARRC with two other beds only (NovoTHOR XL and TheraLight 360). It does not support 'all other full-body systems'. The poster also notes the NovoTHOR showed the highest consistency. source, for the claim 'Research from The Geneva Foundation and OSU (2024)...
- Not supported “'5.5 times more power than leading brand, per Walter Reed'” The only independent study ARRC cites lists Geneva Foundation, Ohio State, AFRL and USU, not Walter Reed. Its averages give ARRC 32.95 vs TheraLight 7.42 mW/cm2 and top canopy 36.48 vs 7.67; no 5.5 ratio appears. source, for the claim '5.5 times more power than leading brand, per Walter Reed'
- Not supported “'Walter Reed and Ohio State in a recent analysis showed ... ARRC LED's ATP and Elysium Device were over 5 times more powerful than the Theralight 360'” The poster names one 'ARRC LED' bed, not the ATP and Elysium separately, and its figures (32.95 vs 7.42 average) do not show a 5x difference. Walter Reed is not a listed institution. source, for the claim 'Walter Reed and Ohio State in a recent analysis showed ......
- Not supported “'operating at a measured 100 mW/cm2, compared to the 30 mW/cm2 output of other devices'” Independent measurements found 32.95 mW/cm2 average (MHSRS 2024) and 46.35 mW/cm2 average with a 53.18 maximum at the bed surface (LightLab 2025). No measurement of 100 mW/cm2 is published. source, for the claim 'operating at a measured 100 mW/cm2, compared to the 30...
- Unverified “'150 mW/cm2 Peak Irradiance'” No distance or instrument is given. ARRC's own homepage says 150 to 160 mW/cm2 readings come from handheld solar meters and that lab spectroradiometers read in the 30s to 40s. No independent test of an Elysium Device was found. source, for the claim '150 mW/cm2 Peak Irradiance'
- Verified “'A 2025 on-site evaluation by LightLab International measured an ARRC RFQ at an average 46.35 mW/cm2 across 20 points'” Matches LightLab report LLIA002780-001-R01. ARRC does not mention that the report was prepared for a competitor (Spectra Red Light) or that one LED line was not working. source, for the claim 'A 2025 on-site evaluation by LightLab International...
- Unverified “Green light at 510 nm (homepage) and 530 nm (Elysium wavelength list)” The two ARRC pages give different green wavelengths. The MHSRS poster did not measure ARRC's green light; LightLab did not report peak wavelengths. source, for the claim Green light at 510 nm (homepage) and 530 nm (Elysium...
Certifications claimed, checked
- Claim only ISO 9001 facilities Stated on the About page; no certificate number or registrar given; not checked against a registrar database. source, for the certification ISO 9001 facilities
- Claim only UL, ETL, IEC 60601, CE or ISO 13485 No such certification claim found on the ARRC pages read (home, Elysium, ATP RFQ, About, FAQ, testimonials). source, for the certification UL, ETL, IEC 60601, CE or ISO 13485
ARRC LED reviews: what buyers report
No Trustpilot, Amazon or BBB rating was found for ARRC LED.
Repeated complaints
No complaint was reported by more than one source.
Repeated praise
No praise was repeated across sources.
ARRC LED on Reddit
- medical grade red light vs prosumer? r/redlighttherapy, 2026-08-14, mixedA user booked a session on an ARRC LED bed and asked if it beats home panels. Replies said comparable home setups cost a fraction as much and that 'medical grade' is a meaningless marketing phrase.
Independent reviewers, forums and video
- Spectra Red Light (competitor) Spectra's page hosts the LightLab report it commissioned on an ARRC RFQ at a client clinic (report cover image and PDF link); the PDF gives a 46.35 mW/cm2 average and notes one LED line not working.Conflict: competitor (Spectra Red Light sells competing beds and commissioned the test)
Claims that did not match the record
- Performance “Elysium page: '150 mW/cm2 Peak Irradiance'”Record: ARRC's homepage says 150 to 160 mW/cm2 figures 'typically come from handheld solar meters' and that calibrated spectroradiometers read 'in the 30s to 40s' on the same bed. Independent results for ARRC: 32.95 mW/cm2 average (MHSRS 2024), 46.35 average and 53.18 maximum (LightLab 2025). Note: neither independent test was of an Elysium Device; the contradiction rests on ARRC's own statement about how 150 to 160 mW/cm2 figures are produced. source, for the record against Elysium page: '150 mW/cm2 Peak Irradiance'
- Performance “About page: 'operating at a measured 100 mW/cm2'”Record: MHSRS 2024: 32.95 mW/cm2 average. LightLab 2025: 46.35 mW/cm2 average, 53.18 maximum at the bed surface. source, for the record against About page: 'operating at a measured 100 mW/cm2'
- Marketing “Homepage: 'ARRC's PATENTED ELYSIUM DEVICE' and 'Patented, designed and built in the USA'”Record: ARRC's own Elysium Device page calls it a 'Patent-Pending Super System'. No patent number is given on either page. source, for the record against Homepage: 'ARRC's PATENTED ELYSIUM DEVICE' and 'Patented,...
- Marketing “ATP RFQ page: '5.5 times more power than leading brand, per Walter Reed'”Record: The cited study is by the Geneva Foundation, Ohio State, AFRL and USU; its averages are 32.95 (ARRC) vs 7.42 (TheraLight) mW/cm2. source, for the record against ATP RFQ page: '5.5 times more power than leading brand, per...
- Marketing “Disclaimer: ARRC 'makes no claims regarding the direct effectiveness of our systems for any condition other than relief from minor aches and pains'; Elysium page: 'treats no condition'”Record: The ATP RFQ page says Superset sessions 'break down pathogens' and Invader Sets use 'frequencies designed to break apart the pathogens'; the testimonials page publishes a diabetic patient's blood sugar falling from the 300s to 107 and 'Dr took him off of meds'. source, for the record against Disclaimer: ARRC 'makes no claims regarding the direct...
Recalls, safety reports and lawsuits
None found in the records checked on 11 November 2026.
Who sells ARRC LED
- Address on record
- 806 E. Avenida Pico, Suite I-267, San Clemente, CA 92673 (ARRC site footer). FDA-registered manufacturing establishment: Semi-Kinetics, Inc. OBO SK Global Trading Inc., 20191 Windrow Dr, Unit A, Lake Forest, CA 92630 (FEI 3003176094).
- Owner or parent
- Not stated on the ARRC site. The FDA owner/operator for the 'ARRC PHOTOBIOMODULATION' listing is SK Global Trading Inc (owner/operator number 10080372), whose contact address (806 E Avenida Pico, Suite I-267, San Clemente) is the same address ARRC prints in its footer. Podcast titles on the ARRC homepage name Mike McIntyre as the company spokesperson. The ARRC FAQ calls ARRC 'an OEM of biotech devices' based in Orange County.
- Customer support
- 855-502-2772; info@arrcled.com
Sources: 1, company record2, company record3, company record4, company record5, company record
ARRC LED: common questions
Is ARRC LED FDA cleared?
FDA registered and listed only, not cleared, per openFDA records checked on 11 November 2026. Registration and listing is a filing by the company. It is not an FDA review of whether the device is safe or works, and it is not a clearance. One FDA claim the brand makes does not match the record; they are quoted below.
Is ARRC LED legit?
On the archive's documentation rule it scores 3 of 5 (partly documented), and its customer record is not rated, because there are not enough reviews. 2 of its FDA, certification, performance or safety claims did not match the record. A score measures how well the seller backs up its claims, not whether the therapy works.
What do ARRC LED reviews and Reddit threads say?
The research read 1 Reddit thread about the brand, each linked on this page.
What wavelengths do ARRC LED devices use?
Across its current devices the brand lists 6 distinct wavelengths: 530 nm, 633 nm, 660 nm, 810 nm, 850 nm and 940 nm. Listed wavelengths are the seller's figures; where an independent test checked the peaks, it is shown in the lab test table.
Has anyone lab tested ARRC LED?
2 optical tests are on record. For example, Hollander, Hagen, Givens, Metzger, Anders, Wagner, Isaacson, Pasquina, Hager measured the 'ARRC LED' bed, model not named.: 20-minute session average 32.95 mW/cm2; horizontal axis average top canopy 36.48 mW/cm2, bottom canopy 33.05 mW/cm2. Poster lists ARRC 'Reported: 76 mW/cm2'. Paid for or supplied by: Project sponsored by the Uniformed Services University, award HU00011920056..
Has ARRC LED had a recall or safety report?
No recall, FDA adverse event report, warning letter or lawsuit was found in the records checked on 11 November 2026.
How these scores work
Documentation score, 5 points
One point each for: wavelengths published; brightness published with the distance it was measured at; a spectroradiometer or integrating sphere test of a current device on file; traceable at FDA through a 510(k) or a registration and listing; no FDA, certification, performance or safety claim contradicted by a record or by a test at the seller's own distance.
5 is fully documented, 4 well documented, 3 partly documented, 0 to 2 thinly documented.
Customer record, 3 points
One point each for: rated 4.0 or better on a review site with 50 or more reviews; a Better Business Bureau grade of A- or better; no single complaint reported by three or more independent buyers or sites. With too few reviews, the record says “not enough reviews to rate” instead of guessing.
Neither score says whether the therapy works. That is what the evidence pages measure.
What could not be verified
- Web search budget for this run was used up before any ARRC review searches ran; Reddit, BBB, Google reviews, YouTube reviews and forums were not searched.
- Reddit returned HTTP 403 for search.json and thread .json requests (old.reddit redirects to a login page); no ARRC Reddit threads were found in locally cached Reddit data.
- Trustpilot: https://www.trustpilot.com/review/arrcled.com returned 404 (no profile at that domain).
- BBB profile not located (BBB site search not run).
- Legal entity behind the ARRC LED trade name not confirmed; the FDA owner/operator SK Global Trading Inc shares ARRC's San Clemente mailing address.
- Founding year unclear: site says 'Epic owners since 2014', 'in business for over 20 years' and LED experience 'reaches back to 2006'.
- MHSRS poster does not name the ARRC model tested, the distance, or who supplied the bed; the reported wavelengths (635/660/850/890/950 nm) differ from the current spec list (530/633/660/810/850/940 nm), so the tested unit may be an earlier configuration.
- No independent test of the Elysium Device or MAX RFQ found; no LED count published per model (blog says 'ARRC LED quotes only 2302' LEDs without naming a model).
No seller paid to be listed or rated. For what red light has been measured to do in people, read the red light evidence.